DHA Exam Questions for ECG Technicians 2026: 12 Free MCQs with Answers on Lead Placement, Paper Speed, Intervals, Artefacts and Rhythms
Back to blog

DHA Exam Questions for ECG Technicians 2026: 12 Free MCQs with Answers on Lead Placement, Paper Speed, Intervals, Artefacts and Rhythms

Twelve free DHA-style MCQs for ECG and cardiac technicians with answers and short explanations, covering paper speed and calibration, chest lead positions, the PR interval, heart rate calculation, artefacts, limb lead reversal, atrial fibrillation and what to do when a patient collapses.

The DHA paper for ECG technicians tests whether you can record a clean, correctly labelled tracing and recognise the rhythms that need urgent attention. These twelve questions show the range. This page is part of our Prometric exam guide; the licence route is in the ECG technician and cardiac perfusionist guide.

12 DHA-style questions for ECG technicians

1. The standard paper speed for a 12-lead ECG is:

A) 25 mm per second B) 10 mm per second C) 50 mm per second D) 100 mm per second

Answer: A. At this speed one large square is 0.2 seconds.

2. At standard speed, one small square on the horizontal axis represents:

A) 0.2 seconds B) 0.1 seconds C) 0.04 seconds D) 1 second

Answer: C. Five small squares make one large square of 0.2 seconds.

3. Lead V1 is placed in the:

A) Fifth intercostal space, midclavicular line B) Fourth intercostal space at the right sternal border C) Second intercostal space on the left D) Left midaxillary line

Answer: B. V2 is the same space at the left sternal border. Find the space by starting from the sternal angle at the second rib.

4. Lead V4 is placed in the:

A) Fourth intercostal space at the left sternal border B) Anterior axillary line C) Midaxillary line D) Fifth intercostal space in the left midclavicular line

Answer: D. V3 goes midway between V2 and V4, and V5 and V6 are level with V4 in the anterior and mid axillary lines.

5. The normal PR interval is:

A) 0.04 to 0.08 seconds B) 0.08 to 0.10 seconds C) 0.12 to 0.20 seconds D) 0.24 to 0.40 seconds

Answer: C. That is three to five small squares. A longer interval indicates first-degree heart block.

6. The rhythm is regular and there are four large squares between R waves. The heart rate is:

A) 60 beats per minute B) 75 beats per minute C) 100 beats per minute D) 150 beats per minute

Answer: B. Divide 300 by the number of large squares.

7. A baseline that drifts slowly up and down is most often caused by:

A) Mains interference B) The wrong paper speed C) A faulty printer D) Patient movement, breathing or poor electrode contact

Answer: D. Prepare the skin, replace dry electrodes and ask the patient to lie still and breathe normally.

8. A fine, regular, thick baseline at 50 or 60 cycles per second is caused by:

A) Electrical interference from nearby equipment B) Shivering C) Deep breathing D) An arrhythmia

Answer: A. Unplug unnecessary devices, move cables apart and check the earth connection. Muscle tremor gives an irregular, spiky baseline.

9. Lead I shows an inverted P wave, QRS complex and T wave, and lead aVR is upright. The likeliest cause is:

A) A heart attack B) Normal variation C) A slow heart rate D) Reversal of the right and left arm leads

Answer: D. Check the limb leads and repeat the recording. Dextrocardia looks similar but the chest leads also progress abnormally.

10. An irregularly irregular rhythm with no visible P waves is:

A) Atrial fibrillation B) Sinus arrhythmia C) Complete heart block D) Ventricular tachycardia

Answer: A. The baseline shows fine fibrillation waves in place of P waves.

11. During a recording the patient becomes unresponsive and the trace turns chaotic. You should first:

A) Repeat the ECG B) Replace the electrodes and continue C) Check the patient, call for help and start resuscitation if there is no pulse or breathing D) Finish printing the trace

Answer: C. Treat the patient, not the monitor. A loose lead can look like an arrest, and a real arrest needs immediate action.

12. Standard ECG calibration is:

A) 5 mm per millivolt B) 10 mm per millivolt C) 20 mm per millivolt D) 1 mm per millivolt

Answer: B. The calibration mark at the start of the trace should be two large squares high. Record any change on the printout.

How the paper works

A timed computer-based MCQ exam covering cardiac anatomy and conduction, lead systems, recording technique, artefacts, basic rhythm recognition, exercise testing and Holter monitoring, patient preparation and safety. Pass marks and attempt rules are in the DHA passing score guide.

How to prepare

After the exam

The application steps are in how to apply for a DHA licence online. You can confirm your title first with the eligibility check.

Frequently asked questions

Who can sit the DHA ECG technician exam?

Holders of a recognised cardiac technology or ECG qualification with the experience DHA requires for the title.

Do I need to interpret ECGs?

At a basic level. You should recognise normal sinus rhythm, the common arrhythmias and the rhythms that need immediate help.

Are stress tests and Holter monitors included?

Yes. Know patient preparation, when to stop an exercise test and how to fit a Holter recorder.

This article is part of our Prometric exam guide: format, booking, fees, results and practice questions for every GCC authority.

Practice banks for this exam

Chapter-wise MCQs with written reasoning on every question, and timed mocks at the real pass mark.